Physical Properties of Cement System Insulation Using Blast Furnace Slag
Article information
Abstract
In this study, fabrication method of inorganic insulation were studied to reduce CO2 from buildings. Main materials for inorganic insulation were used cement, blast furnace slag and aluminum powder as foaming agent. Mixing ratio of cement and slag was controlled and physical properties of inorganic insulation were analyzed. When inorganic insulation was fabricated using cement and slag, expanded slurries were not sunken and hardened normally. Pore size was 0.5 – 2 mm; mean pore size was about 1mm in inorganic insulation. Compressive strength of inorganic insulation increased with curing time and increased slightly with cement fineness. However, specific gravity decreased slightly with curing time; this phenomenon was caused by evaporation of adsorptive water. When inorganic insulation was dried at 60°C, compressive strength was higher than that of undried insulation. The highest compressive strength was found with a mixture of cement (50%) and slag (30%) in inorganic insulation. Compressive strength was 0.32 MPa, thermal conductivity was 0.043 W/mK and specific gravity was 0.12 g/cm3.
1. Introduction
Greenhouse gas emission from buildings accounts for about 25% of the total emission in South Korea. Since the energy consumption at buildings will further increase due to economic growth, the ratio of the greenhouse gas emission from buildings is expected to grow to about 40%.1,2) Accordingly, various methods of reducing energy consumption at buildings have been conducted in South Korea.3–5) Highly efficient and environment-friendly insulation materials have been developed in many countries, and the competitiveness of insulation materials is considered as a reference of national energy utilization efficiency. In advanced countries, such as European countries and Japan, national standards for insulation materials have been amended, and problems of insulation materials (strength, economic feasibility, fire resistance, buildability, human body hazard, etc.) have been overcome.6)
Insulation materials may be classified as organic and inorganic materials; the organic insulation materials include Styrofoam and polyurethane. These materials have excellent thermal insulation properties and are available at a low cost, but may result in large fires and generate hazardous gases in the case of a fire.7,8)
Inorganic insulation materials, such as glass fiber and rock wool, are non-combustible materials that are safe in the case of a fire, but may experience a decrease of insulation and exacerbation of durability when the materials absorb water. To solve these problems, a novel inorganic insulation material for which the water absorption may be controlled needs to be developed. In Germany and other countries, insulation materials having controllable water absorptivity and that are safe against fire are already in use. These materials are inorganic insulation materials manufactured by hydrothermal synthesis at 180°C. A representative example of these materials is Multipor®(Xella), manufactured using cement, lime, and silica powder as raw powder materials and aluminum powder as a foaming agent.9) In hydrothermal synthesis-based manufacturing, these raw materials are mixed with water for foaming. In European countries, a method of using high-fineness cement and a vegetable foaming agent has been studied, but the method has not been completed.10) The room temperature-based method does not require a heat source, but method development is still at the level of fundamental theory because of the poor foaming performance and physical properties. Therefore, systematic research and development work should be carried out continuously to develop a room temperature-based method for manufacturing inorganic insulation materials.
The present study was conducted to develop a room temperature-based method for manufacturing inorganic insulation materials without a heat source. The raw powder materials used were cement and slag; the foaming agent used was an aluminum-based foaming agent. The content of the cement and slag was varied, and the physical properties of the resulting material were analyzed depending on the cement and slag content.
2. Experimental Procedure
A fine slag powder was used to prepare a cement-based inorganic insulation material, because such a powder may effectively show strength at an old material age and provide initial slurry stability (prevention of slurry collapse).
Commercially available ordinary Portland cement (OPC, S Company) was pulverized using a vibration mill, controlling the fineness at 7,500 and 10,000 cm2/g. A fine powder of commercially available slag was obtained and pulverized to a fineness of 7,000 cm2/g. The lime used in the present study was purchased from B Company; anhydrite was from J Company. Table 1 shows the mixing ratios of the cement and slag for the investigation of the properties of the resulting inorganic insulation material. The slag content was varied at 10%, 15%, 20%, 25%, 30%, and 35%; the cement content was varied from 45% to 70%. The content of the lime was fixed at 10% and that of the anhydrite was either 5% or 10%. The ratio of SMK 1311, a chemical admixture for removing gigantic foams and securing foam stability, was fixed at 0.06%, and the content of a silicone-based water-repellent was fixed at 0.1%. The content of the aluminum powder foaming agent was also fixed at 0.6%.
To prepare the primary slurry, powders of OPC, slag, lime, and anhydrite were mixed together. Then, water was mixed in at a ratio of 130% of the binder weight and SMK 1311 was added to prepare the slurry. The mold for the formulation of the slurry was a Styrofoam mold of dimensions 220 × 220 × 220 mm.
The aluminum powder was added to the slurry and the resulting mixture was sufficiently mixed to prepare the final slurry, which was then kept in the air. After about two hours, the slurry expanded to a maximum volume because the reaction between the aluminum powder and the hydrates to produce hydrogen gas was completed within about two hours. Fig. 1 is an image of the final slurry after the foaming was completed. The prepared specimens were removed from the mold 24 h after the preparation of the primary slurry. The specimens removed from the mold were cured at the indoor temperature of 25 ± 2°C and a relative humidity over 60%. The curing period was fixed at 3, 7, 15, and 28 days. After each of the curing periods had passed, the density, compressive strength, and thermal conductivity of the specimens were measured, and the pores in the specimens were also observed.
3. Results and Discussion
3.1. Slurry Preparation Properties
As shown in Fig. 1, all the slag-mixed slurry specimens showed good foaming without slurry setting or collapse (backing, etc.). The internal temperature of all the samples of foaming slurry was below 45°C, but slightly increased as the slag content was increased. However, no correlation between the internal slurry temperature and the slag content was clearly derived. That the foaming slurry showed neither cracking in the cured slurry, nor collapse, even after 24 h, indicated that the cured slurry remained very stable even after 24 h.
Figure 2 shows the pores in the Nos. 2 and 4 slurry specimens after 24 h of curing. The size of the pores in the Nos. 2 and 4 slurry specimens was in a range from about 0.5 to 2 mm; the average pore size was about 1 mm. Some of the pores were connected pores and open pores, while others were closed pores. The close pores may have a positive effect on the insulation performance; they may also contribute to an increase of the compressive strength.11)
3.2. Physical Properties Depending on Number of Curing Days
As described above, the density, compressive strength, and thermal conductivity of the cured slurry specimens were measured after curing for 3, 7, 15, and 28 days. The prepared specimens were cured during each of the curing periods at a temperature of 25 ± 2°C and a relatively humidity of over 60%. Fig. 3 shows the appearance of the specimens after 15 days of curing. All the specimens were in a good condition without cracks.
Figure 4 shows the density of the specimens depending on the curing period. As the curing period was increased, the density decreased. In particular, the density greatly decreased from the material age of 3 days to 7 days. The density slightly decreased when the curing period was increased from 14 days to 28 days. The density was not affected by the slag mixing conditions, while the density was strongly affected by the curing period. This may be because the water included in the cured slurry specimens may have been evaporated more rapidly in the earlier stage of curing.
Figure 5 shows the variation of the compressive strength depending on the cement fineness and the curing period. The compressive strength generally increased with the increase of the curing period and the OPC fineness. Comparing the No. 2 and 4 specimens, having respective fineness values of 10,000 cm2/g and 7,500 cm2/g, the compressive strength of the No. 2 specimen was slightly higher, indicating that the compressive strength slightly increased with the increase of the cement fineness (The compressive strength values of the No. 2 and 4 specimens after the material age of 28 days were 0.3 MPa and 0.28 MPa, respectively). Since the porosity was about 90% and the volume occupied by the matrix was as little as about 10%, the contribution of the matrix was very small, and thus the compressive strength was not significantly dependent on the matrix fineness.
Figure 6 shows the compressive strength depending on the mixing ratios shown in Table 1. As can be seen in Fig. 6, the compressive strength increased with the increase of the curing period. The highest compressive strength values were found at a slag content of 30% (cement content 50%) after 15 days and 28 days of curing period. As the curing period was further increased, the compressive strength gradually decreased as the slag content was decreased and the cement content was increased. The decrease of the compressive strength was caused by both the decrease of the slag content and the increase of the cement content. Generally, when a slag is used, the Pozzolanic reaction occurs, improving the strength. The Pozzolanic reaction is generally known to be enhanced as the curing period increases. However, this is true only when an appropriate amount of slag is used, and thus the Pozzolanic reaction may be dependent on the properties of the specimens and the curing conditions. As shown in Fig. 6(a), the difference of the compressive strength between the specimens was more after 28 days of curing than after 3 days and 7 days of curing. This may be because of the appropriate slag content condition and the difference of the Pozzolanic reactivity.12) Hence, considering the Pozzolanic reactivity, the optimal mixing ratio may be slag 30% and cement 50%. Fig. 6(b) shows the compressive strength data for only a curing period of 28 days, more specifically indicating the gradual decrease of the compressive strength after the peak of the No. 4 specimen mixing condition.
3.3. Physical Properties of Dried Specimens
After completing each of the curing periods, the specimens prepared according to the method described in Section 3.2 were dried and their physical properties were analyzed. The specimens were dried by increasing the temperature by 10°C per hour from 30°C to 60°C. Then, to minimize heat shock to the specimens, the specimens were sufficiently dried at 60°C until the weight became constant. No cracks due to heat shock were found on the specimens after drying. The compressive strength, over-dried density, and thermal conductivity were measured after the drying to review the possibility of using the material as an insulation material.
Figure 7 shows the over-dried density of the specimens. The over-dried density of the specimens was not dependent on the mixing ratios. The density values of all the dried specimens were similar, in a range of 0.11 to 0.12 g/cm3. Fig. 8 shows the compressive strength of the dried specimens. The compressive strength increased with the increase of the curing period. The compressive strength of some specimens was higher than 0.3 MPa after 28 days of curing. The compressive strength of the dried specimens was slightly higher than that of the specimens before drying, indicating that the hydration reaction between the slag and the cement occurred more during the drying process. However, the compressive strength values of each specimen were not different before and after drying. The thermal conductivity of the dried specimens was dependent on neither the curing period nor on the mixing ratio (Fig. 9).
The thermal conductivity of all specimens was in the range of 0.041 to 0.043 W/mK for all the curing periods. In addition, the thermal conductivity values of the No. 3 and 5 specimens were similar at 0.043 W/mK. This shows that the thermal conductivity is not dependent on the hydration reaction between the cement and the slag, but on the pore properties (pore volume and pore type, etc.). Fig. 10 shows the pore characteristics of the No. 4 specimen after drying, as analyzed using an image analyzer (IA). The blue region represents the pores, while the gray region represents the matrix. The image shows that many pores were included in the specimen. The porosity analyzed by the IA was 90.0%, and the average pore size was 0.84 mm. The pore characteristics are consistent with the pore characteristics observed in the slurry cured for 24 h, as shown in Fig. 2. The experimental results verified that the compressive strength was dependent on the drying temperature. Therefore, the drying temperature was increased from 60°C and 80°C. The dryer temperature was increased at a rate of 10°C per hour, and kept at 80°C until the weight became constant. Fig. 11 shows the compressive strength after drying at 80°C.
With the drying temperature of 80°C, the compressive strength did not increase but decreased. After 28 days of curing, the maximum compressive strength was 0.25 MPa, and the minimum compressive strength was 0.17 MPa, indicating that the compressive strength decreased slightly after drying. The decrease of the compressive strength after drying at 80°C may be because of crack generation due to heat shock during drying. The heat shock might have caused thermal degradation of hydrates, such as ettringite, a cement hydrate, as well as shrinkage of the specimen. Therefore, the drying temperature necessary to acquire the maximum compressive strength may be 60°C.
4. Conclusions
In the present study, an inorganic insulation material was prepared at room temperature using cement, lime, and silica powder as raw powder materials, and aluminum powder as a foaming agent. The contents of cement and slag were varied, and the physical properties of the resulting material were analyzed depending on the cement and slag content. The following conclusions were obtained from the present study.
When the insulation material was prepared using cement and slag, the foaming slurry was normally cured without setting. The sizes of the pores in the insulation material were about 0.5 to 2 mm, and the average pore size was about 1 mm.
The compressive strength of the insulation material generally increased with the increase of the curing period. The compressive strength of the insulation material also slightly increased with the increase of the cement fineness. On the other hand, the density gradually decreased as the curing period increased, which may be because the water included in the material evaporated.
At the drying temperature of 60°C, the compressive strength increased after drying. The highest compressive strength was found under the mixing condition of slag 30% and cement 50%. Under that condition, the compressive strength was 0.32 MPa, the thermal conductivity was 0.043 W/mK, and the over-dried density was 0.12 g/cm3. However, as the drying temperature was increased to 80°C, the compressive strength decreased, which may be because the hydrates existing in the insulation material had been thermally degraded.
The present study showed that an inorganic insulation material may be successfully prepared at room temperature by appropriately mixing slag and cement. In addition, the inorganic insulation material prepared at room temperature showed proper compressive strength and thermal conductivity, indicating that the material may be applied to buildings.